  technical d at asheet pmt panel mount power supply 12v 100w 1 phase / pmt - 12v100w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( may 2013 , rev. 0 0) 1 pmt highlights & features ? conforms to harmonic current iec/en 61000 -3 - 2, class a ? selectable ac s witch (90 - 132vac, 180 - 264vac) ? high mtbf > 7 00,000 hrs. as per telcordia sr - 332 ? versatile configuration options (enclosed, l frame) ? versatile connector options (terminal block, front face, harness) safety standards cb certified for worldwide use model number: pmt -12v100 w1a ?? unit weight : 0. 36 kg dimensions (l x w x d): 158 x 97 x 38 mm general description the new pmt series of panel mount power supplies is the latest offering from one of the world?s largest power supply manufact urers and solution providers - delta. the product offers a wide opera ting temperature range from - 10c to +70c and ca n withstand shock and vibration requirements (in accordance to iec 60068 - 2 - 27 and iec 60068 -2 -6 respectively) . in addition to features like overvoltage and overload protections, delta?s pmt series of panel mount power supplies is unlike many other brands in the same price level. the pmt series is designed for cost competitive markets without compromising the quality of the components and product specifications. the series of products has an expected life tim e of 10 years. this versatile series has three different connector options (terminal block, front face and harness) and can also be converted into l frame (pml) type of power supplies to satisfy different application needs. model information pmt panel m ount power supply model number input v oltage range output v oltage output cur r ent pmt -12v100 w1a ?? 90- 132 vac , 180 - 264vac (selectable by switch) 12 vdc 8 .50a model numbering cc code pm ? 12 v 100w 1 a panel mount product type t ? enclosed l ? l frame* output voltage output power single phase no pfc connector type a ? terminal block g ? front face* h ? harness* blank ? without connector cover a ? with connector cover *options
technical d at asheet pmt panel mount power supply 12v 100w 1 phase / pmt - 12v100w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( may 2013 , rev. 0 0) 2 specifications input ratings / characteristics nominal input v oltage 100- 120v ac , 200 - 240vac (selectable by switch) input v oltage range 90- 132v ac , 180 - 264vac (selectable by switch) nominal input f r equency 50- 60hz input f r equency range 47- 63hz input cur r ent < 2.00a @ 115vac, < 1.20a @ 230vac ef ficiency at 100% load > 8 6 .0% @ 115vac & 230vac max inrush cur r ent < 36 a @ 230vac leakage cur r ent < 1ma @ 240vac output ratings / characteristics nominal output voltage 12 vdc output voltage tolerance 1 % (initial set point tolerance from factory ) output voltage adjustment range 11.4 - 13.2 vdc output current 8.50a output power 102w line regulation 0.5% typ. (@ 100 - 132vac & 200- 264vac) load regulation 0.5% typ. (@ 100 - 132vac & 200- 264vac ) pard (20mhz) < 1 50mvp p rise time < 2 0ms @ nominal input (100% load) start - up time < 5 00ms @ nominal input (100% load ) hold - up time > 25 ms @ 115vac , > 30ms @ 230vac dynamic response (overshoot & undershoot o/p voltage) 5% @ 0 - 100% load start - up with capacitive loads 8,000f max mechanical case chassis aluminium case cover sgcc dimensions (l x w x d) 158 x 97 x 38 mm unit weight 0.36 kg indicator green led (dc ok) cooling system convection terminal pm?-12 v100w1a a ? m3.5 x 7 pins (rated 300v/15a) pm ? - 12 v100w1a g ? m3.5 x 7 pins (rated 300v/20a) pm?-12 v100w1a h ? i/p (jwt): a3963wv2 -5p -a o/p (jwt): a3963wv2 - 7p - u wire pm ? - 12 v100w1a a ? / pm ? - 12 v100w1a g ? awg 20 -12 pm?-12 v100w1a h ? awg 20 - 18 (for the recommended housing and terminal, please refer to the table on page 7)
technical d at asheet pmt panel mount power supply 12v 100w 1 phase / pmt - 12v100w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( may 2013 , rev. 0 0) 3 environment surrounding air temperature operating -1 0c to + 7 0 c storage -2 5 c to + 85c power de - rating > 50c de - rate power by 2.5% / c < 115vac de - rate power by 2.5% / 3v operating humidity 10-95 % rh (non - condensing) operating altitude 5 ,000 meters shock test (non - operating) iec60068 - 2 - 27, half sine: 5 0g for a duration of 11ms, 3 times per direction, 18 times in total vibration ( non - operating) iec60068 - 2 - 6, random: 5 hz to 5 00hz @ 2.09g rms, 2 0 min per axis for all x, y, z direction pollution degree 2 protections overvoltage 115- 135% , hicc - up mode, n on - latch ing (auto - recovery) overload / overcurrent 110- 150% , hicc - up mode, non - latching (auto - recovery) over temperature < 7 0 c surrounding air temperature @ 100% load, non - latching (auto - recovery) short circuit hicc - up mode, non- latching (auto - recovery when the fault is removed) protection against shock class i with pe* connection *pe: primary earth reliability data mtbf > 7 00,000 hrs. as per telcordia sr - 332 expected cap life time 10 years (115vac & 230vac , 50% load @ 40c ) safety standards / directives electrical safety tuv bauart to en60950 - 1, ul/cul recognized to ul60950 -1 and csa c22.2 no. 60950 - 1, cb scheme to iec60950 - 1 , ccc to gb4943 ite iec/en/ul 60950 - 1 ce in conformance with emc directive 2004/108/ec and low voltage directive 2006/95/ec material and parts rohs directive 2011/65/eu compliant galvanic isolation input to output 3 .0kvac input to ground 1.5kvac output to ground 0 .5kvac
technical d at asheet pmt panel mount power supply 12v 100w 1 phase / pmt - 12v100w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( may 2013 , rev. 0 0) 4 emc emc / emissions cispr22, en55022, fcc title 47: class b immunity to electrostatic discharge iec 61000 -4 - 2 level 4 criteria a 1) air discharge: 15kv contact discharge: 8kv radiated field iec 61000 -4 - 3 level 3 criteria a 1) 80mhz - 1ghz, 10v/m with 1khz tone / 80% modulation electrical fast transient / burst iec 61000 -4 - 4 level 3 criteria a 1) 2kv surge iec 610 00 -4 - 5 level 3 criteria a 1) common mode 2) : 2kv differential mode 3) : 1 kv conducted iec 61000 -4 - 6 level 3 criteria a 1) 150khz - 80mhz, 10vrms power frequency magnetic fields iec 61000 -4 - 8 criteria a 1) 1 0a/meter voltage dips iec 61000 -4 - 11 100% dip; 1 cycle (20ms); self recoverable low energy pulse test (ring wave) iec61000 - 4 -12 level 3 criteria a 1) common mode 2) : 2kv differential mode 3) : 1kv harmonic current emission iec/en 61000 - 3 - 2, class a voltage fluctuation and flicker iec/en 61000 - 3 -3 1) criteria a: normal performance within the specification limits 2) asymmetrical: common mode (line to earth) 3) symmetrical: differential mode (line to line) block diagram
technical d at asheet pmt panel mount power supply 12v 100w 1 phase / pmt - 12v100w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( may 2013 , rev. 0 0) 5 device description 1 ) input & output terminal block connector 2 ) dc voltage adjustment potentiometer 3 ) dc ok control led (green) dimensions l x w x d: 158 x 97 x 38 mm pmt - 12v100w1a h ? : harness pmt - 12v100w1a a ? : terminal block pmt - 12v100w1a g ? : front face
technical d at asheet pmt panel mount power supply 12v 100w 1 phase / pmt - 12v100w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( may 2013 , rev. 0 0) 6 engineering data de - rating output de - rating vs. input voltage note 1 . power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in fig. 1. 2 . if the output capacity is not reduced when the surrounding air temperature >70 c, the device will run into over temperature protection. when activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3 . in order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm with adjacent units while the device is in opera tion. 4 . depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5 . if the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details. fig. 1 de - rating for vertical and horizontal mounting orientation > 50c de - rate power by 2.5% / c ? no output power de - rating for the input voltage from 115vac to 132vac & 176vac to 2 64vac
technical d at asheet pmt panel mount power supply 12v 100w 1 phase / pmt - 12v100w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( may 2013 , rev. 0 0) 7 assembly & installation mounting holes for power supply assembly onto the mounting surface . ? the power supply shall be mounted on minimum 2 mounting holes using m3 screw minimum 5 mm length. ? this surface belongs to customer?s end system or panel where the power supply is mounted. ? connector ? pm  -12 v100w1a a  / pm  -12 v100w1a g  : use flexible cable (stranded or solid) of awg no. 20 - 12. the torque at the c onnector shall not exceed 13kgf.cm. the insulation stripping length should not exceed 0.275? or 7mm. ? pm  -12 v100w1a h  : use flexible cable (stranded or solid) of awg no. 20 - 18. please refer to tab le 1 for the recommended h ousing and terminal. tab le 1 connector (board mounting) housing terminal input (j w t) a3963wv2 -5p -a a3963h02 -5p a3963t0p -2 output (j w t) a3963wv2 -7 p -u a3963h02 -7p improper installations fig. 2.1 side mounting (vertical) fig. 2.2 base mounting (vertical) fig. 2.3 side mounting (horizontal)
technical d at asheet pmt panel mount power supply 12v 100w 1 phase / pmt - 12v100w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( may 2013 , rev. 0 0) 8 installation of mounting accessories fig. 3 mounting hole locations with reference to fig. 3 , the device should be mounted on a sturdy heat conducting surface with minimum of 4 mounting holes using m3 screw through the base or side mounting holes. safety instructions ? to ensure sufficient convection cooling, always maintain a safety distance of 20mm from all ventilated surfaces while the device is in operation. ? the device is not recommended to be placed on low thermal conductive surfaces, for example, plastics. ? note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. do not touch the device while it is in operation or immediately after power is turned off. risk of burning! ? do n ot touch the terminals while power is being supplied. risk of electric shock. ? prevent any foreign metal, particles or conductors to enter the device through the openings during installation. it can cause : - electric shock; safety hazard; fire; product fail ure. ? the power supply must be mounted by metal screws onto a grounded metal surface. it is also highly recommended that the earth terminal on the connector be connected to the grounded metal surface. ? warning (for standard terminal block and front face term inal block products): when connecting the device, secure earth connection before connecting l and n. when disconnecting the device, remove l and n connections before removing the earth connection. ? only use m3 screw 2.5mm through the base and side mounting holes. this is to keep a safe distance between the screw and internal components. recommended mounting tightening torque: 4 ~ 7kgf.cm. 2.5mm max
technical d at asheet pmt panel mount power supply 12v 100w 1 phase / pmt - 12v100w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( may 2013 , rev. 0 0) 9 functions start - up time the time required for the outpu t voltage to reach 90% of its set value, after the input voltage is applied. rise time the time required for the output voltage to change from 10% to 90% of its set value. hold - up time hold up time is the time when the ac input collapses and output voltage retains regulation for a certain period of time. the time required for the output to reach 95% of its set value, after the input voltage is removed. graph illustrating the start - up time, rise time, and hold- up time inrush current inrush current is the peak, instan taneous, input current measured and, occurs when the input voltage is first applied. for ac input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied ac voltage. this peak value decreases exponentially during subsequent cycles of ac voltage. dynamic response the power supply output voltage will remains within 5% of its steady state value, when su bjected to a dynamic load from 0 to 100% of its rated current.
technical d at asheet pmt panel mount power supply 12v 100w 1 phase / pmt - 12v100w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( may 2013 , rev. 0 0) 10 overload & overcurrent protections the power supply?s overload (olp) and overcurrent (ocp) protections will be activated when output current exceeds 110- 150 % of i o (max load). in such occurrence, the v o will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into ?hiccup mode? (auto - recovery). the power supply will recover once the fault condition of the olp and ocp is removed and i o is back within the specifications. additionally, if the i o is < 110-15 0 % but > 100% for a prolong period of time (depending on the load), the over temperature protection (otp) will be activated due to high temperature on critical components. the power supply will then go into ?hiccup mode? until the fault is removed. overvoltage pr otection the power supply?s overvoltage circuit will be activated when its internal feedback circuit fails. the output voltage shall not exceed its specifications defined on page 3 under ?protections?. over temperature protection as mentioned above, t he power supply also has over temperature protection (otp). this is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. in the event of a higher operating condit ion at 100% load, the power supply will run into otp when the surrounding air temperature is > 7 0 c . when activated, the output voltage will go into bouncing mode until the operating surrounding air temperature drops to 50 c or output capacity is reduced as recommended in the de - rating graph. short circuit protection the power supply?s output olp/ocp function also provides protection against short circuits. when a short circuit is applied, the output current will operate in ?hi ccup mode?, as shown in the illustration in the olp/ocp section on this page. the power supply will return to normal operation after the short circuit is removed. others delta rohs compliant restriction of the usage of hazardous substances the european directive 2011/65/e u limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants pbb and pbde for the use in electrical and electronic equipment. rohs is the abbreviation for ?restriction of the use of certain hazardous substances in electrical and electronic equipment?. this product conforms to this standard. pfc ? norm en 61000 - 3 - 2 line current harmonic content typically, the input current waveform is not sinusodial due to the periodical peak charging of the input capacitor. in industrial environment, complying with en 61000 -3 - 2 is only necessary unde r special conditions. complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific app lication.
mouser electronics authorized distributor click to view pricing, inventory, delivery & lifecycle information: delta: ? pmt-12v100w1aa


▲Up To Search▲   

 